Back

Neural Computation

MIT Press

Preprints posted in the last 7 days, ranked by how well they match Neural Computation's content profile, based on 39 papers previously published here. The average preprint has a 0.03% match score for this journal, so anything above that is already an above-average fit.

1
Identification of the Minimal Clinically Important Difference (MCID) for Childhood Autism Rating Scale Second Edition (CARS2) in children with ASD

Vyshedskiy, A.; Pavoski Poloni, L. E.; Schmiedel Fucks, A.; Khokhlovich, E.; Fucks, E.; Schmiedel, A.

2026-09-04 pediatrics 10.64898/2026.08.31.26361823 medRxiv
Top 0.7%
0.9%
Show abstract

Purpose: In clinical trials, treatment efficacy is commonly assessed by comparing control and treatment groups. However, in large samples, even small and clinically trivial differences may achieve statistical significance. Accordingly, the Minimal Clinically Important Difference (MCID) is used as a threshold to determine whether statistically-significant effects are also clinically meaningful to patients. The objective of this study was to estimate the MCID for the Childhood Autism Rating Scale Second-Edition (CARS2) using the Patient Impression of Change (PIC) as an external anchor. Methods: Single-item PICs are not well suited to characterizing improvement in a multifaceted disorder such as ASD. Accordingly, the 77-item Autism Treatment Evaluation Checklist (ATEC) was used as a multi-item PIC. CARS2 and ATEC were administered concurrently to 62 children with ASD, aged 1.8-7.9 years, with assessments conducted six months apart. Results: The correlation between changes in CARS2 and ATEC total scores was 0.41-0.44 (p<0.0001), supporting the use of ATEC as an anchor measure. Two anchor-based methods yielded MCIDs of 2.39-2.82 CARS2 points. Two distribution-based methods produced MCIDs of 1.33-3.32. Conclusions: Taken together, these approaches suggest that a between-group difference of 2.6 CARS2 points (the midpoint of the anchor-based estimates) may serve as the MCID in children with ASD.

2
Can Dental AI Really Beat Dentists? DentalPair-Cert for Rigorous AI-Dentist Inference

Alve, S. R.; Rahman, S.; Meem, S. M. A. C.

2026-09-02 dentistry and oral medicine 10.64898/2026.09.01.26361874 medRxiv
Top 0.9%
0.5%
Show abstract

A dental AI system and a dentist reading the same radiographs form a paired comparison. Published comparative studies often report the two arms separately against a reference standard, leaving the joint pattern of correctness between them unavailable for secondary paired inference. We show what that omission costs. The accuracy difference remains exactly identified; its sampling variance does not, so the report contains the estimate and not its uncertainty. On a study of 282 units, two published accuracies are consistent with 38 distinct joint tables whose confidence intervals differ in width by a factor of 2.5. The consequence is a three-zone decision map rather than a single threshold: differences at or below 1.06 points are non-significant under every compatible table, differences at or above 6.03 points are significant under every compatible table, and in between the published numbers cannot decide. We then show the omission is repairable at negligible cost. One additional integer, the number of units both arms classify correctly, identifies the joint table exactly and restores standard paired inference. For a panel of readers the pairwise dependences must arise from one joint distribution, a constraint that binds once three readers are present; publishing each reader's joint-correct count against a single reference reader cannot widen and may tighten every pairwise bound, and in a 7-arm experiment reduced them by a median of 37% even for pairs excluding that reference. Where the integer was never published we give DentalPair-Cert, an interval with finite-sample coverage uniformly over every admissible within-unit AI-dentist dependence under the independent-sampling-unit model, certified in both the nuisance maximization and the inversion. Across 4,200,000 simulated comparisons an independence analysis falls to 74.5% coverage with 12.2% type-I error; in a purposive sample of 9 recent comparative studies, 1 reported a paired test on discordant units.

3
Machine learning analysis of Autism phenotype data supports a four-dimensional continuum with three overlapping subtypes

Quigley, H.; Gardiner, B.; McDaid, L.; O'Donnell, C.

2026-08-31 psychiatry and clinical psychology 10.64898/2026.08.27.26361561 medRxiv
Top 1.0%
0.5%
Show abstract

Autism Spectrum Disorder (ASD) is a heterogeneous neurodevelopmental condition defined by differences in social communication and restricted, repetitive behaviours. As diagnostic criteria have broadened, ASD is now recognised across a wider range of individuals, raising key questions about its structure: does ASD have discrete sub-types, or is it better conceptualised as a continuous, possibly multidimensional, condition? We aim to explore whether a multidimensional continuum model more accurately captures the variability within ASD. We analysed a large SPARK phenotypic dataset of medical history and diagnostic surveys (background history, SCQ, RBS-R; n=36,710 individuals). We apply and compare two traditional statistical approaches, Factor Analysis and Gaussian Mixture Models, with a modern machine learning technique, the Variational Autoencoder (VAE). VAEs reconstructed unseen test data with ~4-fold better accuracy than Factor Analysis, and ~8-fold better accuracy than Gaussian Mixture Models. We identified four stable latent factors across 100 independently trained VAEs. These four dimensions provide an individual behavioural profile that can be visualized using radar-plots, offering a compact way to compare profiles at the person level. Through further analysis, we found evidence for 3 overlapping clusters or subtypes of ASD identified within the 4D latent space. This work aims to inform new ways of modelling ASD using a VAE that will be able to discern between a continuum or a clustered output and that go beyond binary diagnosis, instead reflecting the complex range of trait profiles, with implications for personalised diagnosis and intervention.

4
Predicting Conscious Perception from Pupil's Aperture Size Using Machine Learning Techniques

Pandey, P.; Pethe, S. R.; Indrajeet, I.; Ray, S.

2026-08-31 neuroscience 10.64898/2026.08.26.747446 medRxiv
Top 1%
0.3%
Show abstract

Introduction: Decision making for selecting an object or a course of action from possible alternatives largely depends on our perceptual ability modulated by attention. When multiple stimuli appear close together in time, processing one stimulus can temporarily impair the processing of another due to temporal limitations of attention. Observers frequently fail to detect the second target (T2) presented within a few hundred milliseconds after the first target (T1) in a stream of stimuli, which is commonly known as attentional blink (AB). Existing theories attribute this perceptual lapse to T1 processing, distractor interference, or transient attentional gating; however, the computations underlying suppressive mechanism remains unresolved. We investigated whether pupil-size could reveal the underlying mechanisms of AB and predict conscious perception on a trial-by-trial basis. Methods: Pupil diameter and gaze locations were recorded using an infrared eye tracker. Machine learning techniques were used to classify trials when T2 was detected versus when it was not, after correct identification of T1, during an AB task from the pupil dynamics, which also yielded attentional episode (AE) associated with each element in the stream of visual stimuli when deconvolved. Results: Cross-validating classifiers achieved near-perfect accuracy not only in distinguishing but also predicting perceptual outcomes on a single-trial basis. AEs exhibited greater power when T2 was detected than when it was missed; the differential power in AEs on a logarithmic scale was highly synced with the differential pupil size. Conclusions: Collectively, these findings establish a framework for predicting attention-driven perceptual outcomes from pupil-dynamics at finer time-scale.

5
How to pour a cup of coffee

Midlagajni, N.; Fleming, R. W.; Rothkopf, C. A.

2026-09-01 neuroscience 10.64898/2026.08.26.746627 medRxiv
Top 2%
0.1%
Show abstract

Pouring a drink feels deceptively trivial, yet it requires guiding a boundary-free fluid into a vessel without spilling, overflowing, or toppling it -- a task at which robots remain notoriously brittle. How humans achieve this so effortlessly is unknown, as motor control has predominantly been studied in brief, highly constrained laboratory tasks, leaving the control principles underlying ecological tasks largely unknown. Here we measured continuous sensorimotor control during liquid pouring across various containers, vessels, and speed demands. Despite substantial variation in movement trajectories and durations, individuals maintained a strikingly invariant preferred fill level. Counterintuitively, fill level variability decreased at higher fill levels, and precision was maintained even under time pressure. A stochastic optimal control model combining a data-driven nonlinear approximation of flow dynamics with a cost that balanced individualised fill level, energy expenditure and flow-rate reproduced the behaviour. Humans thus pour optimally, given their sensorimotor limits and idiosyncratic notion of "full".

6
Structural generalization and continual learning enabled by factorized entorhinal-hippocampal memory and entorhinal-parietal action circuits

Hwang, J.; Neupane, S.; Jazayeri, M.; Fiete, I.

2026-08-30 neuroscience 10.64898/2026.08.25.747129 medRxiv
Top 2%
0.1%
Show abstract

Flexible behavior requires generalizable memory and learning. For example, we rapidly learn to commute in new cities by reusing our knowledge of Euclidean two-dimensional space and structures like roundabouts and subway systems without forgetting how to get to a favorite restaurant back home. Yet we lack a detailed understanding of how the brain uses existing knowledge to generalize while retaining the memory of specific past experiences. To address this gap, we combine behavioral measurements, neural recordings, and computational modeling in an abstract sequential image navigation task to study three forms of generalization: mnemonic generalization, from visual to mental navigation; transitive generalization, from trained to novel routes; and structural generalization, from familiar to new environments. In contrast to monkeys and humans, recurrent neural networks failed at all generalizations. We found that a structured entorhinal-hippocampal memory model, which provides a content-independent metric scaffold based on grid cells for storing experience, coupled to a policy recurrent network, succeeds at all three. The content-independent scaffold enables mnemonic and transitive generalization through path integration and facilitates structural generalization by allowing reuse of a previously learned action policy network. Moreover, the scaffold's high combinatorial capacity permits continual learning without catastrophic forgetting. We recorded neural activity from the entorhinal cortex and posterior parietal cortex of two monkeys performing the task and found two distinct computations across the neural population. Modularizing an entorhinal and parietal action policy network to separately track distance and initiate actions captured the distinct population dynamics and improved model performance. Finally, we added a reinforcement learning module to the network that enabled it to learn an appropriate scale factor to align the grid periodicity with the environmental temporal structure. Our findings reveal that an architecture which factorizes invariant metric representations from rapid sensory associations and a transferable policy learns, generalizes, and remembers like the brain.

7
Quantifying sprint force-velocity elasticity: implications for individualized training decisions

Li, Z.; Yan, J.; Zhang, X.; Chen, Z.; Li, Q.; Jimenez-Reyes, P.; Janicijevic, D.; garcia-ramos, A.

2026-09-01 biophysics 10.64898/2026.08.29.748040 medRxiv
Top 3%
0.1%
Show abstract

This study aimed to (1) develop an elasticity framework for the sprint force-velocity (F-V) relationship and (2) examine how maximal force (F_{0}), maximal velocity (v_{0}), and sprint distance modulate the four derived elasticity metrics, and (3) explore these elasticity metrics' interrelation. After modelling the F-V relationship differential equation, four elasticity metrics were defined as force elasticity (F_{e}), the elasticity of sprint time to F_{0}; velocity elasticity (v_{e}), the elasticity of sprint time to v_{0}; the force-velocity elasticity norm {(\mathrm{F}-\mathrm{V}}_{\mathrm{EN}}=\sqrt{F_{e}^{2}+v_{e}^{2}}), capturing the combined sprint time sensitivity to proportional changes in F_{0} and v_{0}; and the force-velocity elasticity ratio {(\mathrm{F}-\mathrm{V}}_{\mathrm{ER}}=F_{e}{\div v}_{e}), indicating which variable dominates the sprint time response. Model simulations showed that F_{e} decreased with rising F_{0} and increased with rising v_{0}, while v_{e} showed the opposite pattern. With increasing sprint distance, F_{e} decreased and v_{e} increased. Given its negligible effect on sprint time, ignoring air resistance yields a conservation law (2F_{e}+v_{e}\equiv 1), indicating that a gain in one elasticity metric necessarily diminishes the other in a fixed proportion. This framework also identifies a valley distance (d_{valley}) at {\mathrm{F}-\mathrm{V}}_{\mathrm{ER}}=2, where {\mathrm{F}-\mathrm{V}}_{\mathrm{EN}} is minimized (\sqrt{0.2}) and sprint time is least responsive to changes in F-V relationship variables. Empirical data confirmed that the two theoretical laws still hold approximately when air resistance is considered. By linking changes in F_{0} and v_{0} to sprint time across different distances, the elasticity framework provides a quantitative basis for estimating the theoretical sprint time response to documented changes in F-V relationship variables.

8
Development of a Primary Visual Cortex Model to Investigate Cortical Visual Prosthesis Stimulation

Woolley, J. F.; Meikle, S. J.; Price, N. S. C.; Wong, Y. T.

2026-08-30 neuroscience 10.64898/2026.08.25.746861 medRxiv
Top 3%
0.1%
Show abstract

A new electrical stimulation focused computational model of the visual cortex had been created to aid in the development of cortical visual prosthesis. The model consists of 10,666 biophysical neurons representing 0.13mm3 of a layer 2/3 of the primary visual cortex and was calibrated to match the baseline activity of rat brain recordings. A novel model of electrical stimulation was developed to allow for selective activation of specific neuron types, and matched the single cell stimulation response generated by known stimulation models. The electrode was tuned to match recorded population level change in activity across distances and currents recorded in the rats brain. The model is now ready to explore electrical stimulation effects on the visual cortex for examination of neuron specific stimulation to assist in the development of cortical visual prosthesis.

9
Predictability and controllability shape aversive learning and stress responses through independent computational mechanisms

Rajput, D.; Felmingham, K.; Sophie Lin, C.-H.; Garrido, M.

2026-09-01 neuroscience 10.64898/2026.08.26.745064 medRxiv
Top 4%
0.1%
Show abstract

BACKGROUND: An individual's adaptation to threatening environments under uncertainty is reflected in stress responses. Predictability (the ability to anticipate events) and controllability (the ability to control outcomes) are central to how one adapts, yet their joint influence on aversive learning remains unclear. METHODS: Thirty healthy adults completed a probabilistic aversive learning task in which cue-outcome contingencies varied across levels of predictability and controllability, i.e. whether shock intensity depended on prediction accuracy. Prediction accuracy, reaction time, subjective stress ratings, and skin conductance responses were recorded throughout. Trial-wise learning dynamics were estimated using the Volatile Kalman Filter. RESULTS: Prediction accuracy reduced as environments became less predictable and negatively associated with higher learning rates across predictability levels, with the strongest relationship observed in highly predictable blocks. Skin conductance responses showed that moderately predictable environments elicited responses like those in highly predictable environments when accurate predictions reduced shock intensity, but resembled responses in unpredictable environments when shock intensity was uncontrollable. Model comparison revealed a double dissociation between subjective stress ratings and skin conductance responses. Subjective ratings were best explained by model-derived volatility when prediction accuracy determined shock intensity and by belief uncertainty when it was independent of prediction accuracy, whereas skin conductance responses showed the reverse pattern. Reaction times were best explained by belief uncertainty when predictions influenced shock intensity. Higher anxiety was associated with elevated learning rates in highly and moderately predictable blocks when predictions did not control shock intensity.

10
Burden of fatigue in compensated chronic liver disease: findings from the multinational a:GAP Study

Choudhuri, G.; Akhundova-Unadkat, G.; Naidoo, N.; Morales-Castillo, M.; Guillaume, X.; Duijnhoven, R. G.; Safaei, A.; Swain, M. G.

2026-09-02 gastroenterology 10.64898/2026.08.28.26361618 medRxiv
Top 4%
0.0%
Show abstract

Background & Aims: Fatigue is a central symptom of chronic liver disease (CLD), substantially impacting health-related quality of life (HRQoL). This study aimed to further understand CLD symptomatology, including fatigue, and its impact on HRQoL from a patient perspective. Methods: Abbott Global Assessment of Patients unmet needs (aGAP) was a multinational, cross-sectional survey in adults with compensated CLD in China, India and Mexico, conducted between July and November 2024. Adult participants who self-reported that they had physician-diagnosed CLD and were experiencing fatigue completed a quantitative survey to assess symptom burden and included three HRQoL patient-reported outcome (PRO) questionnaires (Patient-Reported Outcomes Measurement Information System [PROMIS]-29+2, Work Productivity and Activity Impairment - Specific Health Problem version 2.0 [WPAI: SHP], Multidimensional Fatigue Inventory [MFI]). Results: Overall, 505 participants (China: 200; Mexico: 105; India: 200) completed the study. Participants reported that their CLD-related fatigue sometimes, often or always affected their self-esteem/confidence (45.1%) and ability to maintain or acquire new employment (38.6%). Most participants reported moderate (51.3%) or serious (26.9%) fatigue, with 33.5% experiencing fatigue every day or almost every day. Many participants felt their social life was negatively impacted by their fatigue (47.3%) and that there were related financial difficulties (53.9%). Use of validated PRO tools demonstrated severe fatigue (MFI: overall mean [SD] 13.9 [3.4] general fatigue and 13.4 [3.6] physical fatigue) as well as substantial levels of work and activity impairment (WPAI: SHP overall mean [SD] 53.0 [26.4]) and high levels of anxiety, pain interference, depression and sleep interference (PROMIS T-scores [&ge;]54). Conclusions: Fatigue has a substantial impact on HRQoL among adults with CLD across several countries, highlighting a global unmet need for targeted interventions to effectively identify and manage the condition.

11
Are Frontier Large Language Models Safer Than Government-Backed Symptom Checkers for Clinical Self-Triage? A Standardised Vignette Evaluation

Chowdhury, A. R.; Chowdhury, B.

2026-09-02 health informatics 10.64898/2026.09.01.26361908 medRxiv
Top 4%
0.0%
Show abstract

Background: Consumer use of AI chatbots for health advice is rising, yet triage safety relative to established services remains unclear. Australia's Healthdirect, a government-backed symptom checker with 2.4 million uses in FY2024-25, remains unevaluated against frontier large language models (LLMs), and whether premium subscriptions improve triage safety remains unexplored. This study compared the triage accuracy and safety of Healthdirect against six LLM configurations across ChatGPT, Claude, and Gemini, assessed whether paid subscriptions improve triage safety, and characterised each system's error patterns. Methods: Forty-five clinical vignettes from the Semigran et al. benchmark spanning emergency, non-emergent, and self-care categories (15 each) were evaluated across seven systems. Healthdirect was tested following a seven-rule interaction protocol. LLMs were evaluated using first-person patient-language prompts under free-tier and paid-tier conditions. Outcomes were triage accuracy, emergency sensitivity, under-triage, and critical misses, analysed using Cochran's Q, Bonferroni-corrected McNemar tests, Cohen's kappa, and Wilson intervals. Findings: Triage accuracy differed significantly (Cochran's Q = 36.79, p < 0.001). Healthdirect achieved 48.9% accuracy (95% CI 35.0% to 63.0%; kappa = 0.233) versus 73.3% to 86.7% for LLMs (kappa = 0.600 to 0.800). Healthdirect operated under conservative interactive defaults while LLMs received complete information in a single prompt, which may have disadvantaged Healthdirect. Emergency sensitivity was 46.7% versus 80.0% to 86.7% for LLMs. Healthdirect produced two critical misses; no LLM produced any across 270 evaluations (95% CI 0% to 1.4%). When LLMs undertriaged, they recommended GP care rather than self-care. No tier differences were significant (all p > 0.05), and most systems over-triaged self-care cases. Interpretation: Frontier LLMs demonstrated higher triage accuracy and safer error profiles than Healthdirect. All LLMs avoided critical misses; Healthdirect did not. Premium subscriptions did not significantly improve triage safety. These findings support clinical governance decisions about whether LLMs warrant formal evaluation alongside government-backed symptom checkers.

12
ECG-based longitudinal risk prediction across diseases and organ systems

ye, y.; Zeng, Z.; Tian, X.; Yuan, Z.; Wang, J.; Zhu, Y.

2026-09-02 health informatics 10.64898/2026.08.29.26361697 medRxiv
Top 4%
0.0%
Show abstract

Artificial intelligence applied to routine electrocardiograms (ECGs) has largely focused on detecting existing disease or predicting individual cardiovascular outcomes. Whether ECGs can support prediction of multiple future diseases across organ systems remains unclear. We developed ECG-RISK, a multitask survival model for 67 incident three-character ICD-10 endpoints using ECG waveforms, demographic characteristics and routinely collected laboratory data from 86,673 MIMIC-IV patients. Discrimination was highest for heart, brain, kidney and lung endpoints, with organ-level C-indices ranging from 0.796 to 0.825, whereas liver and pancreatic endpoints showed lower discrimination. The ECG-only model achieved strong discrimination across most endpoints, whereas the incremental improvement gained by incorporating ECG and laboratory inputs beyond demographic information varied substantially across endpoints. Across the nine exploratory aggregated outcomes, Kaplan Meier curves showed clear separation among model-score tertiles. Discrimination was highest for dementia (C-index, 0.891) and heart failure (C-index, 0.857). These findings support the feasibility of ECG-based longitudinal risk prediction across multiple diseases. External validation and competing-risk analyses are required to assess generalisability and clinical utility.

13
Certified large language model-based diagnostic decision support in rheumatology: the ALLIANCE multicentre randomised controlled trial

Kremer, P.; Schlicker, N.; Hasnaj, R.; Bamberger, J.; Witte, T.; Haase, I.; Mayr, A.; Schmidt, C.; Osteras, N.; Baraliakos, X.; Kuhn, S.; Krusche, M.; Knitza, J.

2026-09-02 rheumatology 10.64898/2026.08.29.26361715 medRxiv
Top 4%
0.0%
Show abstract

Objectives To evaluate whether access to a certified large language model (LLM)-based clinical decision support system improves physician diagnostic performance in rheumatology compared with conventional diagnostic resources alone. Methods In this multicentre, open-label, randomised controlled trial, 82 physicians from seven hospitals in two countries were randomised 1:1 to conventional diagnostic resources plus Prof. Valmed or conventional resources alone. Participants assessed three rheumatology vignettes before and after assistance. The primary outcome was top-1 diagnostic accuracy. Secondary outcomes included top-3 accuracy, diagnostic reasoning, confidence, case-processing time and perceived support quality. Results Top-1 accuracy increased from 22.2% to 33.3% in the intervention group and from 23.3% to 35.0% in the control group, with no between-group difference in improvement (adjusted OR 0.99, 95% CI 0.45 to 2.19; p=0.979). Differences in top-3 accuracy, diagnostic reasoning and confidence were also not significant. Assisted case-processing time was substantially shorter with LLM support (94 vs 206 s; adjusted mean difference -112 s, 95% CI -141 to -83; p<0.001). Information timeliness and perceived diagnostic support quality were rated significantly higher in the intervention group. Exploratory analyses showed persistent overconfidence and substantial AI over-reliance. Conclusions Certified LLM-based diagnostic support did not improve diagnostic accuracy compared with conventional resources, but substantially reduced case-processing time and improved perceived support quality. These findings suggest potential workflow benefits while highlighting overconfidence and over-reliance as important safety considerations.

14
Optimizing Aqueous Humor Liquid Biopsy: Safety and Performance of a Short, Low-Dead-Space Ophthalmic Needle for Anterior Chamber Paracentesis

Singh, A. M.; Yeh, T.-C.; DeBoer, C.; Al-Moujahed, A.; Lin, J. B.; Smith, S. J.; Sanislo, S.; Janjua, K. A.; Lin, T.-C.; Almeida, D. R. P.; Mruthyunjaya, P.; Mahajan, V. B.

2026-09-02 ophthalmology 10.64898/2026.08.26.26361364 medRxiv
Top 4%
0.0%
Show abstract

Purpose: To evaluate the safety, procedural performance, sample recovery, and surgeon preference of an ophthalmic needle designed specifically for anterior chamber (AC) paracentesis. Methods: In this multicenter study, AC paracentesis was performed in clinic and operating-room settings using a 32-gauge x 4-mm needle with low dead space. The procedure was evaluated using a standardized physician survey. Prespecified outcomes included procedure-related adverse events (primary outcome), needle entry and handling, aspiration and sample recovery, comparative performance versus a 30-gauge needle, and physician preference for future use. Results: A total of 110 needle uses by eight surgeons were included. No ocular complications occurred, including lens or iris injury, hyphema, AC collapse, wound leak, hypotony, infection, or retinal complication, and no procedure required needle exchange or conversion to another device. Two technical events without ocular sequelae were noted, in which needle entry was partial thickness and did not reach the AC (1.8%; exact 95% CI, 0.2%-6.4%). Physicians rated needle entry, handling and sample recovery as good or excellent. Compared with a 30-gauge needle, the study needle was rated as at least comparable across all assessed domains. All surgeons rated it better or much better for intra-procedural safety and preferred it for future AC taps. Conclusions and Relevance: This short, 32-gauge low-dead-space ophthalmic needle demonstrated a favorable safety profile and was preferred over a 30-gauge needle by all surgeons. As aqueous humor liquid biopsy expands in clinical diagnostics and trials, an ophthalmic-specific needle design may help improve the consistency and safety of aqueous humor collection for molecular analysis and broader clinical use. Keywords: Anterior chamber paracentesis; Aqueous humor; Liquid biopsy; Low dead space; Ophthalmic needle

15
Evaluation of the Efficacy and Safety of Combination Therapy of Vamha and Myrha in the Management of PMOS: An Open-Label, Randomized, Multicentre, Comparative, Prospective Clinical Study

Patil, A.; Barathe, R.; Tate, D. M.; Kate, K.; Pande, S.; Gawande, N.; More, A.; Mahadik, S.; Berde, K.; Singhvi, R.

2026-09-02 sexual and reproductive health 10.64898/2026.08.20.26360875 medRxiv
Top 4%
0.0%
Show abstract

Introduction: Polyendocrine metabolic ovarian syndrome (PMOS), formerly known as polycystic ovary syndrome (PCOS), is a common endocrine disorder affecting women of reproductive age. Besides reproductive and metabolic disturbances, PMOS negatively impacts psychological well-being and quality of life. Despite available treatment options, there remains a need for safe and effective therapies that improve both clinical symptoms and fertility outcomes. Aim: To compare the efficacy of VAMHA and MYRHA tablet combination therapy with standard non-hormonal therapy in restoring regular menstruation. Secondary objectives included assessment of ovulation, menstrual symptoms, polycystic ovarian morphology, hormonal and metabolic parameters, anthropometric measures, and skin manifestations. Study Design: Open-label, randomized, multicentre, prospective comparative clinical study. Methods: Seventy-one women with PMOS were randomized to Group A (n=37) or Group B (n=34). Group A received VAMHA and MYRHA tablets (2 tablets each), while Group B received Metformin 500 mg plus Myoinositol 600 mg (1 tablet), twice daily for 180 days. Data were recorded in Case Report Forms. Statistical Analysis: Continuous variables were summarized using mean and standard deviation, while categorical variables were expressed as frequencies and percentages. Appropriate statistical tests, including Chi-square, were used. A p-value [&le;]0.05 was considered significant. Results: Significantly more participants in Group A achieved regular menstrual cycles than Group B (31 vs. 22; p<0.05). Ovulation occurred in 16 participants in Group A compared with 6 in Group B (p<0.05). Both groups showed significant improvement in menstrual irregularity and related symptoms. Significant reductions in Anti-Mullerian Hormone (AMH), fasting insulin, and body mass index (BMI) were observed in both groups (p<0.05). Resolution of polycystic ovarian morphology occurred in 13 participants (38.23%) in Group A and 10 (33.33%) in Group B. Both treatments were well tolerated with no major safety concerns. Conclusions: VAMHA and MYRHA combination therapy was superior to standard non-hormonal therapy in improving menstrual regularity and ovulation. It also produced favourable metabolic, hormonal, and ultrasonographic outcomes, suggesting its potential as a safe and effective option for comprehensive PMOS management and fertility enhancement.

16
An interpretable, formally verified point-of-care ultrasound risk equation for difficult videolaryngoscopy: development and internal validation

Oyarzun-Silva, R. A.; Hernandez-Hernandez, P.; Fernandez-Vaquero, M. A.; De Luis-Cabezon, N.

2026-09-02 anesthesia 10.64898/2026.08.28.26361621 medRxiv
Top 4%
0.0%
Show abstract

Background. Videolaryngoscopy still requires adjuncts or hyperangulated rescue in a clinically important minority, and bedside screening discriminates modestly. Point-of-care ultrasound (POCUS) of the anterior airway is a promising alternative, but existing prediction models are opaque or assume a pre-specified functional form. We developed and internally validated a parsimonious, fully disclosed POCUS risk equation whose form is recovered from data and whose structural properties are machine-checked by formal proof - to our knowledge the first formally verified clinical risk predictor - following TRIPOD+AI 2024. Methods. In a prospective single-centre, single-operator cohort of 259 adults undergoing elective videolaryngoscopy (no-Easy airway 68/259, 26.3%), Sequentially Thresholded Least Squares with bootstrap stability selection (B=300) screened a 71-term library of nine POCUS features and retained a seven-term logistic equation; a two-term bootstrap-stable model was pre-specified as robustness analysis. Internal validation used 5x10 repeated cross-validation plus temporal and device hold-outs, with pre-specified overfitting and optimism assessments. Five behavioural properties of the deployed equation were machine-checked in Lean 4. Results. Two interactions met the |c|/sigma_c>2 stability criterion: skin-to-epiglottis x skin-to-hyoid-bone distance and tongue volume x sagittal tongue area. The seven-term equation reached a 5x10 cross-validated C-statistic of 0.966 (optimism-corrected 0.968) and held across temporal and device hold-outs (0.94-0.97). Calibration-in-the-large matched prevalence, with cross-validated slope 0.90 attenuating to 0.625 out-of-time; standard recalibration restored 0.92 without loss of discrimination. The pre-specified two-term robustness model reproduced this performance (C-statistic 0.964-0.968; events-per-parameter 34; shrinkage 0.99), confirming the result is not an artefact of the screening stage. Net benefit over a clinical baseline was positive across 10-50% thresholds. All five Lean 4 theorems compiled without sorry. Conclusions. A sparse, formally verified POCUS equation predicts difficult videolaryngoscopy with high internally validated discrimination and quantified, modest overfitting. Because the equation was developed in a single-operator cohort and its inputs are operator-dependent, external validation requires prior harmonisation of the measurement protocol and operator credentialing.

17
GLP-1/GIP Uptake, Indication, and Access Pathways Among US Adults in the Understanding America Study

Chaturvedi, R. R.; Gracner, T.; Perez-Arce, F.; Suen, S.-c.; Jin, J.; Orriens, B.; Pacula, R. L.; Sexton Ward, A.; Haile, R.; Kapteyn, A.

2026-09-02 endocrinology 10.64898/2026.08.28.26361368 medRxiv
Top 4%
0.0%
Show abstract

Importance: Evidence on GLP-1/GIP therapies is largely derived from trials enrolling selected populations or medical records that miss utilization outside healthcare channels. No nationally representative cohort has characterized real-world uptake, indications, and access. Objective: To characterize GLP-1/GIP prevalence, indication, clinical profile, and access. Design: Prospective cohort study with three GLP-1/GIP surveillance waves (March 2024, December 2024, October 2025). Setting: The Understanding America Study, an address-based, nationally representative panel of approximately 15,000 US adults aged 18+ years initiated in 2014. Participants: UAS participants responding to at least one surveillance wave (n=9150). Exposures: GLP-1/GIP use status (never vs any use, comprising current and former use), self-reported primary indication (diabetes, weight loss, or other), and access pathway (traditional vs non-traditional). Main Outcomes and Measures: Survey-weighted prevalence of GLP-1/GIP use, overall and by indication and access pathway; sociodemographic, cardiometabolic, treatment, and access characteristics; and smartwatch-derived resting heart rate, heart rate variability, maximum activity heart rate, step count, and sleep duration and variability. Results: Among n=9150 adults (1274 with any use; 60.9% female; median age 53 years), weighted prevalence increased 46%, from 8.2% (March 2024) to 12.0% (October 2025) representing 32 million. Weight-loss indications grew, reaching nearly half of use (4.1% to 5.6%); diabetes-indicated use was stable (5.3% to 5.4%). Users carried high cardiometabolic burden (obesity, 68.2%; diabetes, 53.6%) but diverged by indication: diabetes-indicated users were older (median, 59 vs 49 years), whereas weight-loss-indicated users were more often female (69.9% vs 51.3%) and healthier. One in three users (~9 million) had non-traditional access, especially in weight-loss-indicated users, of whom 33% had no conventional prescription; 41% used compounding, online, or foreign pharmacies; and, 43% lacked coverage. Non-traditional users were five times as likely to report an unlisted, likely compounded formulation (19.8% vs 4.1%). All p<0.05. Conclusions and Relevance: Real-world GLP-1/GIP use has grown rapidly and diversified substantially in indication, access, and population profile. One in 3 users obtained treatment through nontraditional channels largely invisible to claims data, raising long-term safety, efficacy, and coverage questions. GLIMMER provides a public, nationally representative longitudinal evidence base for future payer and provider decisions.

18
Glaucoma and Diabetes Mellitus: A Comparative Evaluation of Comorbid Effect on Tear Quantity among Patients in Owerri, Imo State, Nigeria.

Chukwuoha, C. M.; Ovenseri-Ogbomo, G.; Azuamah, Y. C.; Odimegwu, N. E.; Obioma-Elemba, J. E.; Ugwoke, G.; Nkeremuzor, E. C.; Eronini, Y.; Ikoro, N. C.; Esenwah, E. C.

2026-09-02 ophthalmology 10.64898/2026.08.30.26361782 medRxiv
Top 4%
0.0%
Show abstract

Abstract Objective: Glaucoma is a chronic disorder that impairs ocular health and may exacerbate ocular surface disease leading to tear film instability, dry eye symptoms and decreased quality of life. This study compared changes in tear quantity among glaucoma subjects living with and without diabetes mellitus, attending an eye clinic in Nigeria. Methods: A comparative cross sectional research design was used. 157 subjects which comprised 74 glaucoma subjects living with diabetes mellitus and 83 glaucoma subjects living without diabetes mellitus participated in the study. Tear quantity assessment included the Schirmer I test and tear meniscus height (TMH) measurement. Descriptive statistics, independent samples t-test and Chi-square test were used to examine the data at 0.05 level of significance. Results: Glaucoma subjects living with diabetes mellitus showed substantially decreased tear production (11.4 +/- 6.8 mm) compared with glaucoma subjects living without diabetes mellitus (19.6 +/- 9.6 mm; p < 0.001). Tear meniscus height in glaucoma subjects living with diabetes mellitus (0.8 +/- 0.3 mm) was significantly greater than in subjects living without diabetes mellitus (0.7 +/- 0.3 mm; p = 0.034). Conclusion: Diabetes mellitus dramatically deteriorates the ocular surface function in glaucoma subjects by decreasing tear production, altering the tear meniscus height and increasing the severity of ocular surface symptoms. Routine glaucoma care, especially in patients with diabetes mellitus, should include a full ocular surface evaluation including Schirmer I test, TBUT, TMH, and OSDI assessment to allow early detection and management of ocular surface disease, better treatment adherence, and improved visual outcomes. Keywords: Glaucoma, Diabetes Mellitus, Tear production, Tear Meniscus Height, Ocular Surface Disease.

19
Non-inferior survival and enhanced longevity with initial low-dose versus full-dose enzalutamide: a single-centre real-world prostate cancer study

Gorobets, O.; Vinh-Hung, V.

2026-09-02 oncology 10.64898/2026.08.28.26361616 medRxiv
Top 4%
0.0%
Show abstract

Background: Prostate cancer enzalutamide treatment is approved at a standard dose of 160 mg daily. Concerns for real-world patients -- older and more fragile than those enrolled in clinical trials -- have prompted consideration of initiating treatment with lower doses, but the long-term efficacy of this approach remains unknown. We evaluate the long-term survival and longevity in patients treated with standard versus upfront low-dose enzalutamide. Methods: Retrospective analysis of 151 patients treated with enzalutamide (102 receiving 160 mg; 49 receiving [&le;]80 mg) between 2014--2021 at the Centre Hospitalier Universitaire de Martinique, with complete follow-up through end of life (98.7% completeness of follow-up). Primary outcomes were overall survival (OS), progression-free survival (PFS), and longevity (attained age). Results: Doses [&le;]80 mg were associated with longer median OS (36.3 vs. 20.7 months), improved restricted mean OS (difference of 0.7 years, p=0.05), and enhanced longevity (median 82.5 vs. 78.3 years, p=0.004). PSA response rate at 12 weeks was higher with lower-dose (71.4% vs. 48.8%, p=0.016). In multivariable models adjusted for prognostic factors, [&le;]40 mg compared with 160 mg was non-inferior regarding OS (HR=0.61, 95% CI 0.36--1.06), superior regarding PFS (HR=0.59, 95% CI 0.35--0.99), and superior regarding longevity (HR=0.48, 95% CI 0.28--0.84). Bone metastasis, poor performance status, PSA response, time to PSA nadir, and disease duration were independent predictors of outcomes. A post-hoc analysis revealed a strong association between dose and physician-prescribing profiles, ranging from "endorse-lowest-dose" to "never-deviate-from-full-dose". Conclusions: Lower doses of enzalutamide were non-inferior to full-dose. Dose-adapted strategies warrant further investigation.

20
Maternal cell-free RNA versus combined screening for first-trimester prediction of early-onset preeclampsia: a nested case-control study

Satorres-Perez, E.; Castillo-Marco, N.; Igual, M.; Cordero, T.; Munoz-Blat, I.; Monfort-Ortiz, R.; Marcos-Puig, B.; Simon, C.; Garrido-Gomez, T.; Perales-Marin, A.

2026-09-02 obstetrics and gynecology 10.64898/2026.08.28.26361628 medRxiv
Top 4%
0.0%
Show abstract

Background. In Europe, first-trimester combined screening with the Fetal Medicine Foundation (FMF) algorithm identifies women at increased risk of preeclampsia who may benefit from personalized aspirin prophylaxis. However, a substantial proportion of early-onset preeclampsia (EOPE) remains undetected at clinically acceptable specificity. Objective. To evaluate the first-trimester performance of MaiRa for early-onset preeclampsia (EOPE) risk stratification by benchmarking it against FMF screening in the same women, characterizing discordant patient-level classification profiles and exploring potential implementation strategies. Study Design. This secondary case-control analysis was nested within the prospective, multicentre PREMOM cohort [NCT04990141], which enrolled women with singleton pregnancies across 14 tertiary hospitals in Spain. First-trimester MaiRa and FMF risk estimates were evaluated in the same 126 pregnant women, comprising 99 uncomplicated controls and 27 EOPE cases, defined by disease onset before 34 weeks. Discrimination was compared using a stratified paired bootstrap analysis of the areas under the receiver-operating-characteristic curves. Performance was assessed at prespecified clinical thresholds, and detection rates were evaluated at fixed false-positive rates. Universal and contingent MaiRa implementation strategies were also evaluated. Results. MaiRa showed greater first-trimester discrimination for EOPE than FMF combined screening (AUC, 0.974 vs 0.900; P=.040) and consistently achieved higher detection rates across fixed false-positive rates. At false-positive rates of 5% and 10%, MaiRa detected 85.2% and 92.6% of EOPE cases, compared with 44.4% and 70.4% for FMF, respectively. Patient-level analysis demonstrated that MaiRa identified 12 of 27 EOPE cases (44.4%) classified as low risk by FMF; these pregnancies generally exhibited less abnormal conventional first-trimester profiles, including fewer maternal risk factors, lower mean arterial pressure and lower uterine artery pulsatility index, yet 8 of 12 (66.7%) subsequently developed severe EOPE. Exploratory implementation analyses showed that universal MaiRa screening achieved the highest EOPE detection, whereas a contingent strategy using FMF for triage and reflex MaiRa testing reduced molecular testing to 35.7% of pregnancies while maintaining 77.8% sensitivity and 97.0% specificity. Conclusion. MaiRa provided greater first-trimester discrimination for EOPE than conventional combined screening and detected additional pregnancies that later developed severe disease despite less abnormal conventional screening profiles. The findings suggest that maternal plasma cfRNA profiling captures biological alterations not fully reflected by combined first-trimester screening and support further prospective evaluation in an independent, unselected obstetric population. Key words: early-onset preeclampsia; first-trimester screening; cell-free RNA; liquid biopsy; Fetal Medicine Foundation algorithm; combined screening; risk stratification; aspirin prophylaxis.